Skip to main navigation Skip to search Skip to main content

4D Flow Versus 2D Phase Contrast MRI in Populations With Bi- and Tricuspid Aortic Valves

  • Sofia Hautanen
  • , Teemu Kiljander*
  • , Tarmo Korpela
  • , Petri Saari
  • , Jorma Kokkonen
  • , Pirjo Mustonen
  • , Saara Sillanmäki
  • , Elias Ylä-Herttuala
  • , Minna Husso
  • , Marja Hedman
  • , Petteri Kauhanen
  • *Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

5 Citations (Scopus)
22 Downloads (Pure)

Abstract

Aim: To compare 4D flow magnetic resonance imaging (MRI) and 2D phase contrast (PC) MRI when evaluating bicuspid (BAV) and tricuspid (TAV) aortic valves. Materials and Methods: A total of 83 subjects (35 BAV, 48 TAV) were explored with 4D flow and 2D PC MRI. Systolic peak velocity, peak flow and regurgitation fraction were analysed at two pre-defined aortic levels (aortic root, mid-tubular). Furthermore, the two methods of 4D flow analysis (Heart and Artery) were compared. Results: Correlation between the 2D PC MRI and 4D flow MRI derived parameters ranged from moderate (R=0.58) to high (R=0.90). 4D flow MRI yielded significantly higher peak velocities in the tubular aorta in both groups. Regarding the aortic root, peak velocities were significantly higher in the TAV group with 4D flow MRI, but in the BAV group 4D flow MRI yielded non-significantly lower values. Findings on peak flow differences between the two modalities followed the same pattern as the differences in peak velocities. 4D flow MRI derived regurgitation fraction values were lower in both locations in both groups. Interobserver agreement for different 4D flow MRI acquired parameters varied from poor (ICC=0.07) to excellent (ICC=1.0) in the aortic root, and it was excellent in the tubular aorta (ICC=0.8-1.0). Conclusion: 4D flow MRI seems to be accurate in comparison to 2D PC MRI in normal aortic valves and in BAV with mild to moderate stenosis. However, the varying interobserver reproducibility and impaired accuracy at higher flow velocities should be taken into account in clinical practice when using the 4D flow method.

Original languageEnglish
Pages (from-to)88-98
Number of pages11
JournalIn Vivo
Volume37
Issue number1
DOIs
Publication statusPublished - Jan 2023
Publication typeA1 Journal article-refereed

Funding

The study was supported by funding from Kuopio University Hospital research residue funding (KP 11620), Mauri and Sirkka Wiljasalo Funding, and financial support through a legacy provided by Oiva Vaittinen.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • 2D PC MRI
  • 4D flow MRI
  • bicuspid aortic valve
  • peak velocity
  • tricuspid aortic valve

Publication forum classification

  • Publication forum level 1

ASJC Scopus subject areas

  • General Biochemistry,Genetics and Molecular Biology
  • Pharmacology
  • Cancer Research

Fingerprint

Dive into the research topics of '4D Flow Versus 2D Phase Contrast MRI in Populations With Bi- and Tricuspid Aortic Valves'. Together they form a unique fingerprint.

Cite this