Skip to main navigation Skip to search Skip to main content

Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device

  • Jakub Parak
  • , Adrian Tarniceriu
  • , Philippe Renevey
  • , Mattia Bertschi
  • , Ricard Delgado-Gonzalo
  • , Ilkka Korhonen

    Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Scientific › peer-review

    56 Citations (Scopus)

    Abstract

    PulseOn is a wrist-worn optical heart rate (HR) monitor based on photoplethysmography. It utilizes multiwavelength technology and optimized sensor geometry to monitor blood flow at different depths of skin tissue, and it dynamically adapts to an optimal measurement depth in different conditions. Movement artefacts are reduced by adaptive movement-cancellation algorithms and optimized mechanics, which stabilize the sensor-to-skin contact. In this paper, we evaluated the accuracy and reliability of PulseOn technology against ECG-derived HR in laboratory conditions during a wide range of physical activities and also during outdoor sports. In addition, we compared the performance to another on-the-shelf wrist-worn consumer product Mio LINK®. The results showed PulseOn reliability (% of time with error <10bpm) of 94.5% with accuracy (100% - mean absolute percentage error) 96.6% as compared to ECG (vs 86.6% and 94.4% for Mio LINK®, correspondingly) during laboratory protocol. Similar or better reliability and accuracy was seen during normal outdoor sports activities. The results show that PulseOn provides reliability and accuracy similar to traditional chest strap ECG HR monitors during cardiovascular exercise.
    Original languageEnglish
    Title of host publication2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
    Pages430-433
    Number of pages4
    DOIs
    Publication statusPublished - 2015
    Publication typeA4 Article in conference proceedings
    EventAnnual International Conference of the IEEE Engineering in Medicine and Biology Society -
    Duration: 1 Jan 1900 → …

    Conference

    ConferenceAnnual International Conference of the IEEE Engineering in Medicine and Biology Society
    Period1/01/00 → …

    Publication forum classification

    • Publication forum level 1

    Fingerprint

    Dive into the research topics of 'Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device'. Together they form a unique fingerprint.

    Cite this