Abstract
High voltage capacitors are used in high voltage measurements as a part of a measuring system. According to IEC 60060-2 calibration of voltage measuring system is sufficient with 20 % of nominal voltage. Few methods are presented in the standard how linearity test could be performed for AC measuring system. This paper describes a simple method how to use field sensor to measure capacitance dependency up to nominal voltage. Some linearity test results are presented.
| Original language | English |
|---|---|
| Title of host publication | Proceedings of the Conference on Precision Electromagnetic Measurements (CPEM) |
| Number of pages | 2 |
| Publication status | Published - Dec 2022 |
| Publication type | Not Eligible |
| Event | Conference on Precision Electromagnetic Measurements - Wellington, New Zealand Duration: 12 Dec 2022 → 16 Dec 2022 |
Conference
| Conference | Conference on Precision Electromagnetic Measurements |
|---|---|
| Country/Territory | New Zealand |
| City | Wellington |
| Period | 12/12/22 → 16/12/22 |
Fingerprint
Dive into the research topics of 'Field sensor for linearity measurement of high voltage capacitor'. Together they form a unique fingerprint.Equipment
-
High Voltage Laboratory
Lahti, K. (Contact)
Electrical EngineeringFacility/equipment: Research infrastructure