Skip to main navigation Skip to search Skip to main content

Glycaemic control in insulin deficient patients using different insulin delivery and glucose sensoring devices: Cross-sectional real-life study

Research output: Contribution to journalArticleScientificpeer-review

16 Downloads (Pure)

Abstract

Aims: To assess glycaemic control in ≥15-year-old patients with type 1 diabetes treated in Tampere University Hospital in a real-life cross-sectional registry study. Methods: Glycaemic control was assessed with HbA1c, time in range (TIR) and the incidence of acute complications. The effect of age, BMI, gender, duration of diabetes, daily insulin dose, and device group on the glycaemic control was studied. Results: The study included 1,132 patients. Eighty-four percent of the patients had TIR≤70%. Two percent of patients had an episode of diabetic ketoacidosis and 0,2% had severe hypoglycemia within the last 12 months. Intermittently scanned CGM (IsCGM) with MDI was used in 59%, continuous subcutaneous insulin infusion (CSII) with glucose sensor in 15%, and sensor-augmented/hybrid closed-loop pump (SAP/HCL) in 9% of the patients. In the logistic regression analysis, TIR≤70% was associated with young age group (OR 2.70; 95% CI 1.43–5.09) and daily insulin dose per weight (OR 6.66; 95% CI 3.53–12.57). CSII with glucose sensor and IsCGM with MDI were associated with poor glycaemic control compared to SAP/HCL. Conclusion: There is room for improvement in the glycaemic control in our area although serious acute complications are rare. Closed insulin pump system was more effective than open system.

Original languageEnglish
Article number100072
Number of pages7
JournalDiabetes Epidemiology and Management
Volume7
DOIs
Publication statusPublished - 2022
Publication typeA1 Journal article-refereed

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Blood glucose monitoring
  • Diabetic ketoacidosis
  • Glycemic control
  • Insulin pump
  • Time in range
  • Type 1 diabetes

Publication forum classification

  • Publication forum level 1

ASJC Scopus subject areas

  • Internal Medicine
  • Endocrinology, Diabetes and Metabolism

Fingerprint

Dive into the research topics of 'Glycaemic control in insulin deficient patients using different insulin delivery and glucose sensoring devices: Cross-sectional real-life study'. Together they form a unique fingerprint.

Cite this