Skip to main navigation Skip to search Skip to main content

Inspiratory Profiles Through Easyhaler Dry Powder Inhaler During Acute Bronchoconstriction

  • Ville A. Vartiainen
  • , Antti Tikkakoski
  • , L. Pekka Malmberg
  • , Liisa Vuotari
  • , Satu Lähelmä*
  • , Ulla Sairanen
  • , Mikko Vahteristo
  • , Jussi Karjalainen
  • , Lauri Lehtimäki
  • *Corresponding author for this work

Research output: Contribution to journal › Article › Scientific › peer-review

3 Citations (Scopus)
30 Downloads (Pure)

Abstract

Background: Dry powder inhalers (DPIs) are passive devices, which rely on a patient’s inspiratory effort for drug dispersion and delivery. The aim of this study was to assess how acute bronchoconstriction affects the ability to use Easyhaler DPI in adults. Methods: This study was conducted as part of a parallel-group clinical trial assessing use of Salbutamol Easyhaler, Budesonide-formoterol Easyhaler and salbutamol pMDI with spacer during a methacholine challenge (MC) test. The inhalations through both Easyhaler variants, the inhaler for the single active substance product (EH-mono) and the inhaler for the combination product (EH-combi), were recorded at baseline and during bronchoconstriction. Peak inspiratory flow (PIF), flow rate acceleration and inhalation volume after PIF were compared to the criteria for successful inhalation. Results: The study population consisted of 120 adult subjects indicated for MC as a diagnostic test for asthma, with 60 subjects in both Easyhaler arms. With EH-combi 98.3% and 91.4% passed the criteria (PIF ≥30 L/min, inhalation acceleration ≥0.7 L/s2, and inhalation volume ≥500 mL after PIF) for successful inhalation at baseline and during bronchoconstriction, respectively. With EH-mono, success rates were 95.0% and 88.1% at baseline and during bronchoconstriction, respectively. The most common reason for not passing the criteria was slow inhalation acceleration. Aside from two subjects using EH-mono during bronchoconstriction, all subjects were able to generate PIF ≥ 30 L/min. Conclusions: During an acute obstructive event, the vast majority of patients have no difficulty in achieving sufficient PIF, inhalation acceleration, and volume after PIF when using an Easyhaler DPI.

Original languageEnglish
Pages (from-to)83-89
Number of pages7
JournalJournal of Aerosol Medicine and Pulmonary Drug Delivery
Volume38
Issue number2
Early online date2025
DOIs
Publication statusPublished - 2025
Publication typeA1 Journal article-refereed

Keywords

  • dry powder inhaler
  • obstruction
  • peak inspiratory flow rate

Publication forum classification

  • Publication forum level 1

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Pharmaceutical Science
  • Pharmacology (medical)

Fingerprint

Dive into the research topics of 'Inspiratory Profiles Through Easyhaler Dry Powder Inhaler During Acute Bronchoconstriction'. Together they form a unique fingerprint.

Cite this