Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?

Shadi Mahdiani, Vala Jeyhani, Mikko Peltokangas, Antti Vehkaoja

    Research output: Chapter in Book/Report/Conference proceedingConference contributionScientificpeer-review

    40 Citations (Scopus)
    4406 Downloads (Pure)

    Abstract

    With the worldwide growth of mobile wireless technologies, healthcare services can be provided at anytime and anywhere. Usage of wearable wireless physiological monitoring system has been extensively increasing during the last decade. These mobile devices can continuously measure e.g. the heart activity and wirelessly transfer the data to the mobile phone of the patient. One of the significant restrictions for these devices is usage of energy, which leads to requiring low sampling rate. This article is presented in order to investigate the lowest adequate sampling frequency of ECG signal, for achieving accurate enough time domain heart rate variability (HRV) parameters. For this purpose the ECG signals originally measured with high 5 kHz sampling rate were down-sampled to simulate the measurement with lower sampling rate. Down-sampling loses information, decreases temporal accuracy, which was then restored by interpolating the signals to their original sampling rates. The HRV parameters obtained from the ECG signals with lower sampling rates were compared. The results represent that even when the sampling rate of ECG signal is equal to 50 Hz, the HRV parameters are almost accurate with a reasonable error.
    Original languageEnglish
    Title of host publication2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
    Pages5948-5951
    Number of pages4
    DOIs
    Publication statusPublished - 2015
    Publication typeA4 Article in conference proceedings
    EventAnnual International Conference of the IEEE Engineering in Medicine and Biology Society -
    Duration: 1 Jan 1900 → …

    Conference

    ConferenceAnnual International Conference of the IEEE Engineering in Medicine and Biology Society
    Period1/01/00 → …

    Keywords

    • Accuracy
    • Databases
    • Electrocardiography
    • Heart rate variability
    • Interpolation
    • Rail to rail inputs
    • Time-domain analysis

    Publication forum classification

    • Publication forum level 1

    ASJC Scopus subject areas

    • Biomedical Engineering

    Fingerprint

    Dive into the research topics of 'Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?'. Together they form a unique fingerprint.

    Cite this