Novel optical technologies for emergency preparedness and response: Mapping contaminations with alpha-emitting radionuclides

Maksym Luchkov, Volker Dangendorf, Ulrich Giesen, Frank Langner, Claudia Olaru, Mastaneh Zadehrafi, Annika Klose, Kim Kalmankoski, Johan Sand, Sakari Ihantola, Harri Toivonen, Clemens Walther, Stefan Röttger, Mihail Razvan Ioan, Juha Toivonen, Faton S. Krasniqi

Research output: Contribution to journalArticleScientificpeer-review

8 Citations (Scopus)
26 Downloads (Pure)

Abstract

Radiological emergencies involving an accidental or deliberate dispersion of alpha-emitting radionuclides in the environment can cause significant damage to humans and societies in general. Currently, there is a metrology gap in managing such emergencies due to the lack of detectors that can measure alpha particles at distances greater than their range in air: most conventional alpha detectors are only effective when placed just a few centimeters above the contaminated area. This paper presents the development and testing of lens based optical detection systems that utilize alpha particle-induced ultraviolet (UV) luminescence of air, known as alpha radioluminescence. Telescopes based on fused silica and Poly(methyl 2-methylpropenoate) (PMMA) Fresnel lenses were investigated for their usability in facilitating emergency management related to alpha-emitting radionuclides. Careful matching of the diameter and focal length of the receiving optics, the response of the photocathode, and the passband of the filter allows detection sensitivities as high as 34s−1MBq−1 at 2m source-to-detector distance and background count rate of about 3s−1 in the UV-C spectral region, and suppression of daylight background count rate down to 16s−1. By flushing the source with nitrogen (N2) containing trace amounts of nitric oxide (NO), a groundbreaking sensitivity of 1.3×105s−1MBq−1 has been achieved, allowing detection limits as low as 100Bq with room lighting on, and 70Bq in a dark environment. In the UV-A spectral region, a detection limit of 4kBq could be achieved in a dark environment. These optical detection systems are aimed to facilitate a rapid, coordinated, and effective response in emergency situations involving the release of alpha-emitting radionuclides by mounting them on a tripod or an unmanned aerial device (UAV).

Original languageEnglish
Article number167895
Number of pages9
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume1047
Early online date9 Dec 2022
DOIs
Publication statusPublished - Feb 2023
Publication typeA1 Journal article-refereed

Keywords

  • Emergency preparedness
  • Lens-based detection systems
  • Optical detection of alpha emitters
  • Radioluminescence
  • UV-A
  • UV-C

Publication forum classification

  • Publication forum level 1

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Fingerprint

Dive into the research topics of 'Novel optical technologies for emergency preparedness and response: Mapping contaminations with alpha-emitting radionuclides'. Together they form a unique fingerprint.

Cite this