    Electrical impedance pneumography signal is a valuable tool in qualifying better the person’s health condition. It can be used in monitoring of respiration rate, rhythm and tidal volume. Impedance pneumography has also the potential in ambulatory physiological monitoring systems that are increasingly often implemented using plaster-like on-body devices. In such cases, the area of electrode substrate may be limited and therefore, the electrode configuration, which is able to provide both a clinically valuable electrocardiogram signal and accurate pulmonary information, is an issue. EAS is a useful small area electrode configuration that can be used for electrocardiogram measurements. In this work, different two-electrode bipolar pairs of EAS system are tested for impedance pneumography measurements. Two additional electrodes are also considered in these tests. Our results show that the electrode pair S-A provides the most accurate respiration cycle length and is least affected by movement artifact. Additionally, the results show that this electrode pair produces the signals with highest amplitude.

    Original languageEnglish
    Title of host publicationXIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016
    Subtitle of host publicationMEDICON 2016, March 31st-April 2nd 2016, Paphos, Cyprus
    PublisherSpringer Verlag
    Pages1138-1143
    Number of pages6
    ISBN (Print)9783319327013
    DOIs
    Publication statusPublished - 2016
    Publication typeA4 Article in conference proceedings
    EventMediterranean Conference on Medical and Biological Engineering and Computing -
    Duration: 1 Jan 2000 → …

    Publication series

    NameIFMBE Proceedings
    Volume57
    ISSN (Print)1680-0737

    Conference

    ConferenceMediterranean Conference on Medical and Biological Engineering and Computing
    Period1/01/00 → …

    Keywords

    • Electrode
    • Impedance
    • Location
    • Pneumography
    • Respiration

    Publication forum classification

    • Publication forum level 1

    ASJC Scopus subject areas

    • Biomedical Engineering
    • Bioengineering

    Fingerprint

    Dive into the research topics of 'Optimal short distance electrode locations for impedance pneumography measurement from the frontal thoracic area'. Together they form a unique fingerprint.

    Cite this