Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor

Laura Salo, Jian Gao, Sampo Saari, Erkka Saukko, Kauko Janka, Topi Rönkkö, Jorma Keskinen

    Research output: Other conference contributionPosterScientific

    Abstract

    Pegasor’s AQ Indoor sensor (AQI) uses a new
    method for evaluating the count median diameter
    (CMD) of an aerosol (Saukko, 2016). A modified ion
    trap cycles voltages from 1 to 1000 V, trapping
    charged particles along with ions. The larger the
    particles, the lower their electrical mobility and the
    larger the trap voltage needed to remove them.
    Original languageEnglish
    Publication statusPublished - 28 Aug 2017
    Publication typeNot Eligible
    EventEuropean Aerosol Conference 2017 - Zürich, Switzerland
    Duration: 27 Aug 20171 Sept 2017

    Conference

    ConferenceEuropean Aerosol Conference 2017
    Country/TerritorySwitzerland
    CityZürich
    Period27/08/171/09/17