@inproceedings{d50ec9d50ba841d7af4cbe3f28673b45,
title = "Possibilities to decrease the electric field exposure with a shield over worker under the 400 kV power lines",
abstract = "The aim of the paper was to present examples of electric field measurements using a piece of shielding net under power lines and above the subject. We performed experiments under power lines using a ladder and constructed different shield nets. We conducted five experiments: (1) ladder was not grounded, (2) ladder was grounded; (3) ladder with a 60×60 cm fish net shield (grounded); (4) ladder with 145 × 60 cm fish net shield (grounded); and (5) the ladder with a chicken net shield (grounded). In the measurement place, the electric field was 5.1 kV/m (height 1.7 m). Our experimental shields could decrease the electric field relatively well.",
keywords = "Electric variables measurement, Electromagnetics, Europe, Grounding, Health and safety, Sparks, Steel",
author = "Rauno P{\"a}{\"a}kk{\"o}nen and Leena Korpinen and Hiroo Tarao and Fabriziomaria Gobba",
note = "EXT={"}Tarao, Hiroo{"}; Progress in Electromagnetics Research Symposium ; Conference date: 01-01-1900",
year = "2016",
month = nov,
day = "10",
doi = "10.1109/PIERS.2016.7735159",
language = "English",
publisher = "IEEE",
pages = "2934--2936",
booktitle = "2016 Progress in Electromagnetic Research Symposium (PIERS)",
}