Automatic assessment of the myoclonus severity from videos recorded according to standardized Unified Myoclonus Rating Scale protocol and using human pose and body movement analysis

Jelena Hyppönen, Anna Hakala, Kaapo Annala, Honglei Zhang, Jukka Peltola, E Mervaala, Reetta Kälviäinen

Tutkimustuotos: ArtikkeliScientificvertaisarvioitu

Abstrakti

Purpose: Myoclonus in progressive myoclonus epilepsy type 1 (EPM1) patients shows marked variability, which presents a substantial challenge in devising treatment and conducting clinical trials. Consequently, fast and objective myoclonus quantification methods are needed. Methods: Ten video-recorded unified myoclonus rating scale (UMRS) myoclonus with action tests were performed on EPM1 patients who were selected for the development and testing of the automatic myoclonus quantification method. Human pose and body movement analyses of the videos were used to identify body keypoints and further analyze movement smoothness and speed. The automatic myoclonus rating scale (ARMS) was developed. It included the jerk count during movement score and the log dimensionless jerk (LDLJ) score to evaluate changes in the smoothness of movement. Results: The scores obtained with the automatic analyses showed moderate to strong significant correlation with the UMRS myoclonus with action scores. The jerk count of the primary keypoints and the LDLJ scores were effective in the evaluation of the myoclonic jerks during hand movements. They also correlated moderately to strongly with the total UMRS test panel scores (r2 = 0,77, P = 0,009 for the jerk count score and r2 = 0,88, P = 0,001 for the LDLJ score). The automatic analyses was weaker in quantification of the neck, trunk, and leg myoclonus. Conclusion: Automatic quantification of myoclonic jerks using human pose and body movement analysis of patients’ videos is feasible and was found to be quite consistent with the accepted clinical gold standard quantification method. Based on the results of this study, the automatic analytical method should be further developed and validated to improve myoclonus severity follow-up for EPM1 patients.

AlkuperäiskieliEnglanti
Sivut72-78
Sivumäärä7
JulkaisuSeizure: European Journal of Epilepsy
Vuosikerta76
DOI - pysyväislinkit
TilaJulkaistu - 2020
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Tutkimusalat

  • EPM1
  • Myoclonus
  • Pose estimation analysis
  • Unified Myoclonus Rating Scale

Julkaisufoorumi-taso

  • Jufo-taso 1

Sormenjälki

Sukella tutkimusaiheisiin 'Automatic assessment of the myoclonus severity from videos recorded according to standardized Unified Myoclonus Rating Scale protocol and using human pose and body movement analysis'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.