Effect of single-current-feedback active damping on the output impedance of grid-connected inverter

Aapo Aapro, Tuomas Messo, Teuvo Suntio

    Tutkimustuotos: KonferenssiartikkeliTieteellinenvertaisarvioitu

    2 Sitaatiot (Scopus)

    Abstrakti

    LCL-filter is commonly used as an output-side filter in a grid-connected converter due to its good attenuation capability at the switching harmonic frequencies. LCL-filter creates several resonances in the converter dynamics which shall be damped for ensuring robust performance of the converter. The resonant behavior introduced by the LCL-filter can be attenuated with active damping (AD) instead of passive damping to improve the conversion efficiency. The active damping affects the output impedance of the converter, and the impedance should be accurately predicted in order to allow analyzing impedance-based stability of power electronics-based power systems. This paper presents the small-signal model for inverter-current-feedback (ICF) converter using only the inverter-side inductor current feedback for both control and active damping. Additionally, the output impedance properties are comprehensively analyzed. Experimental measurements from 3-kW prototype are presented to verify the analysis.
    AlkuperäiskieliEnglanti
    Otsikko2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)
    KustantajaIEEE
    Sivut1-10
    Sivumäärä10
    ISBN (elektroninen)978-9-0758-1524-5
    DOI - pysyväislinkit
    TilaJulkaistu - 27 lokak. 2016
    OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisussa
    TapahtumaEUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS -
    Kesto: 1 tammik. 1900 → …

    Julkaisusarja

    Nimi
    ISSN (painettu)2325-0313

    Conference

    ConferenceEUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS
    Ajanjakso1/01/00 → …

    Julkaisufoorumi-taso

    • Jufo-taso 1

    Sormenjälki

    Sukella tutkimusaiheisiin 'Effect of single-current-feedback active damping on the output impedance of grid-connected inverter'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

    Siteeraa tätä