Siirry päänavigointiin Siirry hakuun Siirry pääsisältöön

Non-invasive radioiodine imaging for accurate quantitation of NIS reporter gene expression in transplanted hearts

  • Davide Ricci
  • , Ari A Mennander
  • , Linh D Pham
  • , Vinay P Rao
  • , Naoto Miyagi
  • , Guerard W Byrne
  • , Stephen J Russell
  • , Christopher G A McGregor

Tutkimustuotos: ArtikkeliTieteellinenvertaisarvioitu

15 Sitaatiot (Scopus)

Abstrakti

OBJECTIVE: We studied the concordance of transgene expression in the transplanted heart using bicistronic adenoviral vector coding for a transgene of interest (human carcinoembryonic antigen: hCEA - beta human chorionic gonadotropin: betahCG) and for a marker imaging transgene (human sodium iodide symporter: hNIS).

METHODS: Inbred Lewis rats were used for syngeneic heterotopic cardiac transplantation. Donor rat hearts were perfused ex vivo for 30 min prior to transplantation with University of Wisconsin (UW) solution (n=3), with 10(9) pfu/ml of adenovirus expressing hNIS (Ad-NIS; n=6), hNIS-hCEA (Ad-NIS-CEA; n=6) and hNIS-betahCG (Ad-NIS-CG; n=6). On postoperative day (POD) 5, 10, 15 all animals underwent micro-single photon emission computed tomography/computed tomography (SPECT/CT) imaging of the donor hearts after tail vein injection of 1000 microCi (123)I and blood sample collection for hCEA and betahCG quantification.

RESULTS: Significantly higher image intensity was noted in the hearts perfused with Ad-NIS (1.1+/-0.2; 0.9+/-0.07), Ad-NIS-CEA (1.2+/-0.3; 0.9+/-0.1) and Ad-NIS-CG (1.1+/-0.1; 0.9+/-0.1) compared to UW group (0.44+/-0.03; 0.47+/-0.06) on POD 5 and 10 (p<0.05). Serum levels of hCEA and betahCG increased in animals showing high cardiac (123)I uptake, but not in those with lower uptake. Above this threshold, image intensities correlated well with serum levels of hCEA and betahCG (R(2)=0.99 and R(2)=0.96, respectively).

CONCLUSIONS: These data demonstrate that hNIS is an excellent reporter gene for the transplanted heart. The expression level of hNIS can be accurately and non-invasively monitored by serial radioisotopic SPECT imaging. High concordance has been demonstrated between imaging and soluble marker peptides at the maximum transgene expression on POD 5.

AlkuperäiskieliEnglanti
Sivut32-39
Sivumäärä8
JulkaisuEuropean Journal of Cardio-thoracic Surgery
Vuosikerta33
Numero1
DOI - pysyväislinkit
TilaJulkaistu - 2008
Julkaistu ulkoisestiKyllä
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Sormenjälki

Sukella tutkimusaiheisiin 'Non-invasive radioiodine imaging for accurate quantitation of NIS reporter gene expression in transplanted hearts'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä