Optimal short distance electrode locations for impedance pneumography measurement from the frontal thoracic area

Vala Jeyhani, Tiina Vuorinen, Kai Noponen, Matti Mäntysalo, Antti Vehkaoja

    Tutkimustuotos: KonferenssiartikkeliScientificvertaisarvioitu

    39 Lataukset (Pure)

    Abstrakti

    Electrical impedance pneumography signal is a valuable tool in qualifying better the person’s health condition. It can be used in monitoring of respiration rate, rhythm and tidal volume. Impedance pneumography has also the potential in ambulatory physiological monitoring systems that are increasingly often implemented using plaster-like on-body devices. In such cases, the area of electrode substrate may be limited and therefore, the electrode configuration, which is able to provide both a clinically valuable electrocardiogram signal and accurate pulmonary information, is an issue. EAS is a useful small area electrode configuration that can be used for electrocardiogram measurements. In this work, different two-electrode bipolar pairs of EAS system are tested for impedance pneumography measurements. Two additional electrodes are also considered in these tests. Our results show that the electrode pair S-A provides the most accurate respiration cycle length and is least affected by movement artifact. Additionally, the results show that this electrode pair produces the signals with highest amplitude.

    AlkuperäiskieliEnglanti
    OtsikkoXIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016
    AlaotsikkoMEDICON 2016, March 31st-April 2nd 2016, Paphos, Cyprus
    KustantajaSpringer Verlag
    Sivut1138-1143
    Sivumäärä6
    ISBN (painettu)9783319327013
    DOI - pysyväislinkit
    TilaJulkaistu - 2016
    OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisussa
    TapahtumaMediterranean Conference on Medical and Biological Engineering and Computing -
    Kesto: 1 tammik. 2000 → …

    Julkaisusarja

    NimiIFMBE Proceedings
    Vuosikerta57
    ISSN (painettu)1680-0737

    Conference

    ConferenceMediterranean Conference on Medical and Biological Engineering and Computing
    Ajanjakso1/01/00 → …

    Julkaisufoorumi-taso

    • Jufo-taso 1

    !!ASJC Scopus subject areas

    • Biomedical Engineering
    • Bioengineering

    Sormenjälki

    Sukella tutkimusaiheisiin 'Optimal short distance electrode locations for impedance pneumography measurement from the frontal thoracic area'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

    Siteeraa tätä