Signal-to-noise ratio is more important than sampling rate in beat-to-beat interval estimation from optical sensors

Sebastian Zaunseder, Antti Vehkaoja, Vincent Fleischhauer, Christoph Hoog Antink

    Tutkimustuotos: ArtikkeliScientificvertaisarvioitu

    17 Sitaatiot (Scopus)

    Abstrakti

    Photoplethysmographic Imaging (PPGI) allows the determination of pulse rate variability from sequential beat-to-beat intervals (BBI) and pulse wave velocity from spatially resolved recorded pulse waves. In either case, sufficient temporal accuracy is essential. The presented work investigates the temporal accuracy of BBI estimation from photoplethysmographic signals. Within comprehensive numerical simulation, we systematically assess the impact of sampling rate, signal-to-noise ratio (SNR), and beat-to-beat shape variations on the root mean square error (RMSE) between real and estimated BBI. Our results show that at sampling rates beyond 14 Hz only small errors exist when interpolation is used. For example, the average RMSE is 3 ms for a sampling rate of 14 Hz and an SNR of 18 dB. Further increasing the sampling rate only results in marginal improvements, e.g. more than tripling the sampling rate to 50 Hz reduces the error by approx. 14%. The most important finding relates to the SNR, which is shown to have a much stronger influence on the error than the sampling rate. For example, increasing the SNR from 18 dB to 24 dB at 14 Hz sampling rate reduced the error by almost 50% to 1.5 ms. Subtle beat-to-beat shape variations, moreover, increase the error decisively by up to 800%. Our results are highly relevant in three regards: first, they partially explain different results in the literature on minimum sampling rates. Second, they emphasize the importance to consider SNR and possibly shape variation in investigations on the minimal sampling rate. Third, they underline the importance of appropriate processing techniques to increase SNR. Importantly, though our motivation is PPGI, the presented work immediately applies to contact PPG and PPG in other settings such as wearables. To enable further investigations, we make the scripts used in modelling and simulation freely available.

    AlkuperäiskieliEnglanti
    Artikkeli103538
    JulkaisuBiomedical Signal Processing and Control
    Vuosikerta74
    DOI - pysyväislinkit
    TilaJulkaistu - huhtik. 2022
    OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

    Julkaisufoorumi-taso

    • Jufo-taso 1

    !!ASJC Scopus subject areas

    • Signal Processing
    • Health Informatics

    Sormenjälki

    Sukella tutkimusaiheisiin 'Signal-to-noise ratio is more important than sampling rate in beat-to-beat interval estimation from optical sensors'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

    Siteeraa tätä