    Abstrakti

    Heat soak testing of tempered glass is a thermal process required after the tempering process itself to bring glasses of commercial soda-lime-silica-glass to failure that are contaminated with nickel sulphide inclusions, diameter 50 mm to 500 mm typically. Thus, the tests avoid a so-called "spontaneous" breakage of the glass in building elements at ambient temperatures months or years later. According to industry standards, the duration of the tests typically differs between 1 h and 4 h at temperatures of 290 ± 10 °C. Although this temperature is well below the transformation temperature of commercial soda-lime-silica glass, it causes stress relaxation in tempered glass and the fracture pattern of the glass changes accordingly, especially thin glasses are affected. Based on the Tool-Narayanaswamy-Model, this paper comprises the theoretical background of the stress-relaxation-process and the results of a parameter study for its most influential technical parameters. Results are compared to photoelastic measurements of temper stresses and fracture patterns of tempered glass before and after a heat treatment similar to heat soak testing.

    AlkuperäiskieliEnglanti
    Sivut42-49
    Sivumäärä8
    JulkaisuEngineering Structures
    Vuosikerta122
    DOI - pysyväislinkit
    TilaJulkaistu - 1 syysk. 2016
    OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

    Julkaisufoorumi-taso

    • Jufo-taso 2

    !!ASJC Scopus subject areas

    • Civil and Structural Engineering

    Sormenjälki

    Sukella tutkimusaiheisiin 'Stress relaxation in tempered glass caused by heat soak testing'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

    Siteeraa tätä